MIL-G-58103
c. Switch shall be mounted in grip assembly; i.e., grip assembly
shall be considered part of the switch housing.
d. Radiated emissions shall not exceed levels shown in Figures
13 and 18 of MIL-STD-461A (Notice 4).
3.3.6.2 Conducted Mission. Measurements shall be made in accordance
with requirements of MIL-E-6051 (spikes). The following conditions shall
apply:
a. Loads switched - dc resistive at 28 volts and rated current of
switch or grip assembly wiring, whichever is less.
b.
Switch shall be actuated with a non-conductive rod.
c. Switch shall be mounted in grip assembly; i.e., grip assembly
shall be considered part of the switch housing.
d. Spikes (transients) shall not exceed +50 percent nor -150 per-
cent of the dc line voltage.
3.3.7 Drawings. In addition to 76-7477-1, -2, drawings forming a part of
this specification are contractor supplied engineering design drawings as
approved by the contracting officer. Each supplier is responsible for pre-
paring his own shop drawings as necessary. Where tolerance prescribed
could cumulatively result in incorrect fits, the supplier shall provide
tolerances with those prescribed by contracting officer approved draw-
ings to insure correct fit, assembly, and operation of the grip. No devi-
ation from the prescribed dimensions or tolerances is permissible without
prior approval of the contracting officer. Contractor prepared drawings
which are required for submittal to the government shall be in accordance
with DOD-D-1000 and shall include linear dimensions and tolerances in both
US customary units and metric units. Screw threads shall be specified in
US customary units only.
3.3.8 Screw Threads.
Unless otherwise specified, screw threads shall con-
form with MIL-S-7742.
3.3.9 Electrical Wiring. All hookup, interwiring, or cabling shall use
wire conforming with MIL-W-81044 or MIL-W-16878, Type B.
3.3.10 Soldering, Unless otherwise specified, soldering shall conform
with MIL-STD-454, Requirement 5.
3.3.11 Labels. Labels shall be attached at each switch to identify its
function. The labels shall be removable so that legends may be altered in
the event that switch function is changed, but shall be emplaced in a
manner to insure against inadvertent removal in normal use or in cleaning.
Letters and numerals on the labels shall be in accordance with MIL-M-18012.
5
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business