MS28131H
NOTES
1. MARKING SHALL BE RAISED .030 MINIMUM AND PAINTED TO CONTRAST.
SUBSTITUTE THE PROPER IDENTIFICATION FOR (A) AND (B) AS LISTED IN
TABLE I. IF A "C" CONNECTION IS REQUIRED, IT SHALL BE IDENTIFIED BY
"CPR".
2. ZERO ADJUSTMENT PROTECTION SHALL BE TO THE CASE AND ACCESS TO OR OPERATION OF THE ADJUSTMENT MECHANISM SHALL NOT REQUIRE DETACHMENT OF PARTS. LOCKWIRING IS PERMISSIBLE PROVIDED IT IS INTENDED PRIMARILY TO DISCOURAGE UNAUTHORIZED ADJUSTMENT AND IS NOT THE SOLE MEANS OF PREVENTING MOVEMENT DURING TRANSMITTER USAGE.
3. DIMENSIONS ARE IN INCHES.
4. METRIC EQUIVALENT S (TO THE NEAREST .01mm) ARE GIVEN FOR GENERAL INFORMATION ONLY AND ARE BASED UPON 1 INCH � 25.4mm.
5. REFERENCED DOCUMENTS SHALL BE OF THE ISSUE IN EFFECT ON DATE OF INVITATIONS FOR BIDS OR REQUEST FOR PROPOSAL EXCEPT THAT REFERENCED ADOPTED INDUSTRY DOCUMENTS SHALL GIVE THE DATE OF THE ISSUE ADOPTED.
6. FOR DESIGN FEATURE PURPOSES, THE STANDARD TAKES PRECEDENCE OVER PROCUREMENT DOCUMENTS REFERENCED HEREIN.