MIL-PRF-38230D
4.5.4 Operating life span. After satisfactory completion of the reliability test, and if specified
in the acquisition document (see 6.2) an operating life span of 3,000 hours shall be
demonstrated by continuing the reliability test. The transmitter shall be repaired when failures
occur and testing continued until the transmitter has operated 3,000 hours.
4.5.5 Compatibility. The transmitter shall be connected to and tested with indicators specified
in MIL-I-25437, MIL-I-25438, MIL-I-27189, and MIL-I-38133. The transmitter and indicators
shall be connected as shown in figure 1. The scale error test in MIL-PRF-25435 shall be
performed at ambient temperature. The tolerance at each test point shall be the sum of the
tolerances in table I of this document and table I of MIL-I-25438 at ambient temperature.
5.
PACKAGING
5.1
Packaging. For acquisition purposes, the packaging requirements shall be as specified in
the contract or order (see 6.2). When packaging of materiel is to be performed by DoD
personnel, these personnel need to contact the responsible packaging activity to ascertain
requisite packaging requirements. Packaging requirements are maintained by the Inventory
Control Point packaging activity within the Military Department or Defense Agency, or within
the Military Department's System Command. Packaging data retrieval is available from the
managing Military Department or Defense Agency automated packaging files, CD-ROM
products, or by contacting the responsible packaging activity.
6.
NOTES
(This section contains information of a general or explanatory nature which may be helpful, but
is not mandatory.)
6.1
Intended use. The transmitters covered by this specification are intended for use with
variable-reluctance-type indicators conforming to MIL-I-25437, MIL-I-25438, MIL-I-27189,
and MIL-I-38133 in oil pressure indicating systems.
Acquisition requirements. Acquisition documents must specify the following:
6.2
a. Title, number, and date of this specification.
b. Item identification (see 3.6).
c. Type of transmitter required (see 1.2).
d. Data to be submitted with the qualification samples.
e. If a reliability test is waived (see 4.4.4).
f. If an operating life span test is required (see 4.4.5).
g. Packaging requirements (see 5.1).