MIL-DTL-27189E
3.5.2.1.1 Perfect Reflectance (MS24576-3). All reflecting glass surfaces of the MS24576-3 indicator shall be
provided with a reflection reducing coating which meets the requirements of MIL-C-675 with the exception of the
materials use, in addition to withstanding the environmental conditions specified herein. The following reflectance
tolerances shall apply:
Angle of
Wavelength
Percent
Incidence
Millimicrons
Reflectance
0o
450-675
0.6 absolute
0o
425-700
0.5 average
30o
400-625
1.0 absolute
30o
425-700
0.5 average
3.5.3 Reliability. The indicator shall have a minimum acceptable mean-time-between-failures (MTBF) of 2,000
hours based upon a discrimination ratio of 1.5 and confidence factor of 90 percent.
3.5.3.1 Longevity. The indicator shall have an operating life span of 3,000 hours.
3.6 Performance.
3.6.1 Tolerances. The indicator shall operate within the tolerances specified inTables I and II.
TABLE I. Temperature Scale Error.
Scale Error
High and Low Temp Exposure
Test Pressure, PSI
Room Temperature, PSI
High and Low Temperature, PSI
0
1.5
3.00
10
1.5
3.00
20
1.5
3.00
30
1.5
3.00
40
1.5
3.00
50
1.5
3.00
60
1.5
3.00
70
1.5
3.00
80
1.5
3.00
90
1.5
3.00
100
1.5
3.00
TABLE II. Position, Friction, and Vibration Error.
Test
Tolerance +PSI
Position error at 50 psi
1.5
Friction
Room temperature
1.5
High temperature
2.0
Low temperature
2.25
Vibration
Pointer oscillation
2.0
Pointer variation
1.5
3